V1000 High Output Frequency Specification

V1000 compact size inverter drive running induction motors with an output frequency between 0.0 and 1000.0 Hz for excellent motor drive performance.

The implemented Safe Torque Off (STO) function replaces output contactors and significantly improves machine safety and reliability and provides substantial cost reduction potentials.

  • Long life design for 10 years of maintenance-free operation.
  • Fast Acceleration / Deceleration
  • High peak current capability for rapid start and stop.
  • Time required for tool changes at spindles is minimised increasing the time-efficiency of machine cycles.

Spindle Drives for Machine Tools

Technical Details

Ratings 1 ~ 200V .... 240V +10%/-15%, 0.1kW to 4.0kW
3 ~ 200V .... 240V +10%/-15%, 0.1kW to 18.5kW
3 ~ 380V .... 480V +10%/- 15%, 0.2kW to 18.5kW
Applicable Motor Induction Motor (IM)
Synchronous Motor (PM)
Control V/f Control
Open Loop Vector (OLV)
Open Loop Vector (OLV) for PM
Speed Control Range V/f and V/F with PG 1:40
OLV 1:100
CLV and OLV for PM 1:10*3
Max. Output Frequency 1,000 Hz
Fieldbus Interfaces RS-232C
RS-422/485 (Memobus/Modbus)
MECHATROLINK-I
MECHATROLINK-II
Ethernet/IP
EtherCAT
Modbus TCP
PROFINET
CC-Link
DeviceNet
PROFIBUS-DP
CANopen
Standards CE
UL/cUL
RoHS
UL508C
EN ISO 13849-1 PLd
IEC/EN61508 SIL2
Enclosure IP20, NEMA1, IP66 Finless types
Functions Speed/Torque Control Switching
Energy Saving Function
Double Rating (ND/HD)
Speed Search
Slip Compensation
Torque Compensation
PID Control (with sleep function)
DriveWorksEZ (PLC SW)
Momentary Power Loss Ride-Thru
Application Parameter Presets
Preventive Maintenance Functions
RS-232C Interface